JPE, Vol. 18, No. 4, July 2018
Loss Minimization Control of Interior Permanent Magnet Synchronous Motors Considering Self-Saturation and Cross-Saturation
Hamidreza Pairo, Mohammad Khanzade, and Abbas Shoulaie
Area Adjustable Speed Drives
Abstract In this paper, a loss minimization control method for interior permanent magnet synchronous motors is presented with considering self-saturation and cross saturation. According to variation of the d-axis and q-axis inductances by different values of the d-axis and q-axis components of currents, it is necessary to consider self-saturation and cross saturation in the loss minimization control method. In addition, the iron loss resistance variation due to frequency variation is considered in the condition of loss minimization. Furthermore, the loss minimization control method is compared with maximum torque per ampere (MTPA), unity power factor (UPF) and id=0 control methods. Experimental results verify the performance and proper dynamic response of the loss minimization control method with considering self-saturation and cross saturation.
Keyword Loss minimization,Maximum efficiency control method,Permanent magnet synchronous motor,Self-saturation and cross-saturation