Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients


Vol. 16, No. 1, pp. 48-56, Jan. 2016
10.6113/JPE.2016.16.1.48


PDF    

 Abstract

This paper proposes a method for detecting irreversible demagnetization using the harmonic analysis of back electromotive force (BEMF) in interior permanent magnet-type brushless DC motors. First, demagnetization patterns, such as equality, inequality, and weighted demagnetizations, are defined and classified by considering the possibility of demagnetization resulting from motor operating characteristics. Second, an available diagnostic model for the harmonic analysis of BEMFs is defined according to pole?slot coefficients because the characteristics of BEMFs under demagnetization conditions are affected by the combination of poles and slots. Third, BEMFs and their harmonic components under normal and demagnetization conditions are analyzed through simulation and experiment to verify the proposed demagnetization detection technique.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

D. Kang, H. Kim, J. Park, S. Hyun, J. Hur, "Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients," Journal of Power Electronics, vol. 16, no. 1, pp. 48-56, 2016. DOI: 10.6113/JPE.2016.16.1.48.

[ACM Style]

Dong-Hyeok Kang, Hyung-Kyu Kim, Jun-Kyu Park, Seung-Ho Hyun, and Jin Hur. 2016. Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients. Journal of Power Electronics, 16, 1, (2016), 48-56. DOI: 10.6113/JPE.2016.16.1.48.