A Study of a Simple PDP Driver Architecture using the Transformer Network


Vol. 8, No. 2, pp. 148-155, Apr. 2008
10.6113/JPE.2008.8.2.148


PDF    

 Abstract

In this paper, a cost-effective PDP driving circuit using the transformer network is proposed. Compared with the previous works, the half-bridge type energy recovery circuit recovers the reactive energy not to the capacitor but to the source. A single sustain board architecture removes the blocking switches which are placed on the discharge path in parallel, thus reducing the number of devices. A simple reset circuit generates the same waveform as the previous approaches. The circuit configuration and modified driving waveforms are compared with the previous works. The validity of the proposed simplified driver is verified through tests using a 6-inch panel.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

W. Kim, J. Shin, S. Chae, B. Hyun, B. Cho, "A Study of a Simple PDP Driver Architecture using the Transformer Network," Journal of Power Electronics, vol. 8, no. 2, pp. 148-155, 2008. DOI: 10.6113/JPE.2008.8.2.148.

[ACM Style]

Woo-Sup Kim, Jong-Won Shin, Su-Yong Chae, Byung-Chul Hyun, and Bo-Hyung Cho. 2008. A Study of a Simple PDP Driver Architecture using the Transformer Network. Journal of Power Electronics, 8, 2, (2008), 148-155. DOI: 10.6113/JPE.2008.8.2.148.