A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame


Vol. 9, No. 5, pp. 718-725, Sep. 2009
10.6113/JPE.2009.9.5.718


PDF    

 Abstract

To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

J. Kim and Y. Kim, "A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame," Journal of Power Electronics, vol. 9, no. 5, pp. 718-725, 2009. DOI: 10.6113/JPE.2009.9.5.718.

[ACM Style]

Jin-Sun Kim and Young-Seok Kim. 2009. A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame. Journal of Power Electronics, 9, 5, (2009), 718-725. DOI: 10.6113/JPE.2009.9.5.718.