Improved neutral shift method for fault tolerant operation of three phase MLCI


Vol. 21, No. 1, pp. 49-58, Jan. 2021
10.1007/s43236-020-00161-0




 Abstract

In a three-phase multilevel cascaded inverter (MLCI), when a failed module is bypassed, the number of modules in each phase becomes unbalanced. Under this condition, a method to obtain a balanced three-phase output is to move the neutral point of the MLCI. The neutral-point shift (NS) method has attracted a great deal of attention since the output of the inverter has a relatively low harmonic distortion when compared to other fault-tolerant operation methods. To move the neutral point, an offset voltage of the fundamental frequency component is injected. If the injected offset voltage exceeds the available range of the offset voltage, overmodulation occurs. Then, the output of the inverter is distorted. In this paper, the overmodulation regions of the NS method are analyzed for the fault-tolerant operation in the three-phase MLCI. In addition, a modified NS method is proposed to compensate for the overmodulation region. Both simulation and experimental results in a two-by-three MLCI demonstrate the performance of the proposed method.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

J. Kim and Y. Cho, "Improved neutral shift method for fault tolerant operation of three phase MLCI," Journal of Power Electronics, vol. 21, no. 1, pp. 49-58, 2021. DOI: 10.1007/s43236-020-00161-0.

[ACM Style]

Jeongwoo Kim and Younghoon Cho. 2021. Improved neutral shift method for fault tolerant operation of three phase MLCI. Journal of Power Electronics, 21, 1, (2021), 49-58. DOI: 10.1007/s43236-020-00161-0.