Effects of Zero-Sequence Transformations and Min-Max Injection on Fault-Tolerant Symmetrical Six-Phase Drives with Single Isolated Neutral


Wan Noraishah Wan Abdul Munim†,*, Mahdi Tousizadeh*, and Hang Seng Che*


Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam, Malaysia

*UMPEDAC Research Centre, University of Malaya, Kuala Lumpur, Malaysia



Abstract

Recently, there has been increased interest in the study of multiphase machines due to their higher fault-tolerant capability when compared to their conventional three-phase counterparts. For six-phase machines, stator windings configured with a single isolated neutral (1N) provide significantly more post-fault torque/power than two isolated neutrals (2N). Hence, this configuration is preferred in applications where post-fault performance is critical. It is well known that min-max injection has been commonly used for three-phase and multiphase machines in healthy condition to maximize the modulation limit. However, there is a lack of discussion on min-max injection for post-fault condition. Furthermore, the effects in terms of the common-mode voltage (CMV) in modulating signals has not been discussed. This paper investigates the effect of min-max injection in post fault-tolerant control on the voltage and speed limit of a symmetrical six-phase induction machine with single isolated neutral. It is shown that the min-max injection can minimize the amplitude of reference voltage, which maximizes the modulation index and post-fault speed of the machine. This in turn results in a higher post-fault power.


Key words: Current control, Fault-tolerant, Min-max injection, Multiphase machine, Symmetrical six-phase


Manuscript received Jan. 9, 2019; accepted Mar. 8, 2019

Recommended for publication by Associate Editor Zhonggang Yin.

Corresponding Author: aishahmunim@salam.uitm.edu.my, Tel: +60193355309, Universiti Teknologi MARA

*UMPEDAC Research Centre, University of Malaya, Malaysia



Ⅰ. INTRODUCTION

The recent increase in interest on multiphase machines is, to a large extend, motivated by the rising demand for fault-tolerant drives in applications such as electric vehicles, off-shore wind farms, more-electric aircraft, etc., where the reliability of the drives are of great concern. Studies on the fault-tolerant capabilities, topologies and control of multiphase machines have flourished over the past two decades [1]. 

A recent generalized study on six-phase machines, which included symmetrical six-phase (S6), asymmetrical six-phase (A6) and dual three-phase (D3) machines, demonstrated that the post-fault capabilities of six-phase machines depend heavily on the winding configuration [2]. Furthermore, the study suggested that for a six-phase machine supplied with a six-leg inverter, the single isolated neutral (1N) configuration is superior to the two isolated neutrals (2N) configuration in terms of post-fault power/torque. For the case of a S6 machine, the 1N configuration can yield a maximum of 54.2% more post-fault torque than 2N. Hence, the 1N configuration should be selected in applications where fault-tolerance is prioritized. Despite the clear post-fault advantage, it is known configuring a six-phase machine with 1N allows additional zero-sequence current to flow in the machine and demands more control effort than the 2N configuration. Nevertheless, there has been a lack of discussions on the effect of post-fault control on the voltage and speed limit of S6 induction machines with the 1N configuration using min-max injection.

In this paper, a study on min-max injection for the post-fault control of a S6 induction machine with the 1N configuration is presented. This study is focused on the fault- tolerant control performance of the S6-1N using different common-mode voltages (CMVs) injected to the modulating signals. It is demonstrated that there are multiple phase voltage references (i.e. inverter leg voltages) that can give rise to the same machine phase voltages. This means that for the same post-fault currents, the voltage references generated by the controller may be different depending on the choice of the current regulator structure. With the carrier-based PWM method, a higher voltage references may result in premature over-modulation, which restricts the maximum operating speed (which in turn effects the maximum post-fault power) of the machine. Subsequently, it is demonstrated here that, regardless of the CMV, the use of zero-sequence (min-max) signal injection can minimize the amplitude of the reference voltage, which maximizes the modulation index.

Over the years, several fault-tolerant control strategies have been proposed for multiphase machines [3]-[6], including six-phase machines [7]-[12]. Despite their differences, the majority of these methods are based on the field oriented control (FOC) method [13], where the machine phase variables are transformed into stationary or rotating reference frame variables using a suitable transformation matrix before being controlled using controllers such as the PI-controller, PR- controller, predictive controller, etc. The control strategies rely on the choice of decoupling transformation (or extended Clarke transformation) matrix [T] which can be broadly classified into two categories: control using reduced-order transformation (ROT) [8], [10], [14]-[17] and control using full-order transformation (FOT) [9], [18]-[21]. Between the two, the FOT approach provides a simpler control that uses the same transformation matrices and the same machine parameters, with minimal changes to the control structure when the machine transit from healthy into post-fault operation. In terms of the current controller, a dual synchronous reference frame PI controller (DSRF-PI) or PR controller is recommended for the control of non-torque/flux producing currents since these currents are generally AC quantities [3], [12], [21], [22].

For the FOT fault-tolerant control of a six-phase machine using the vector space decomposition (VSD) approach, a 6×6 decoupling transformation matrix [T] is used to transform the phase variables into α, β, x, y, 0+ and 0- decoupled components

그림입니다.
원본 그림의 이름: CLP000027d82920.bmp
원본 그림의 크기: 가로 1598pixel, 세로 73pixel     (1)

For machines with distributed windings, it is generally accepted that α-β components contribute to flux and torque production, while x-y and 0+0- components only lead to losses (i.e. non torque/flux producing current). However, in post- fault operation, these loss-producing x-y and 0+0- currents can be manipulated to drive a six-phase machine according to different operation requirements such as Minimum Loss (ML), Maximum Torque (MT) [2] or Full- Range Minimum Loss (FRML) [24].

In the literature, there are two six-phase decoupling transformation matrices that are commonly considered for a S6 machine. They are given as follows:

그림입니다.
원본 그림의 이름: CLP000027d80001.bmp
원본 그림의 크기: 가로 1597pixel, 세로 328pixel     (2)

그림입니다.
원본 그림의 이름: CLP000027d80002.bmp
원본 그림의 크기: 가로 1715pixel, 세로 371pixel     (3)

where 그림입니다.
원본 그림의 이름: CLP000027d80003.bmp
원본 그림의 크기: 가로 560pixel, 세로 71pixel.

The main difference between the two decoupling matrices 그림입니다.
원본 그림의 이름: CLP000027d80005.bmp
원본 그림의 크기: 가로 193pixel, 세로 75pixel and 그림입니다.
원본 그림의 이름: CLP000027d80004.bmp
원본 그림의 크기: 가로 152pixel, 세로 75pixel lies in the transformations for the 0+ and 0- components, which are the last two rows of the matrices.

If the six-phase windings are treated as two separate sets of three-phase windings, i.e. a1b1c1 and a2b2c2, the zero- sequence currents for each respective winding set can be defined as:

그림입니다.
원본 그림의 이름: CLP000027d80006.bmp
원본 그림의 크기: 가로 542pixel, 세로 180pixel     (4)

It is easy to see that the zero-sequence currents in 그림입니다.
원본 그림의 이름: CLP000027d80004.bmp
원본 그림의 크기: 가로 152pixel, 세로 75pixel represent the zero-sequence currents of individual three-phase windings, i.e.:

그림입니다.
원본 그림의 이름: CLP000027d80007.bmp
원본 그림의 크기: 가로 559pixel, 세로 116pixel     그림입니다.
원본 그림의 이름: CLP000027d80008.bmp
원본 그림의 크기: 가로 306pixel, 세로 105pixel      (5)

On the other hand, 그림입니다.
원본 그림의 이름: CLP000027d80005.bmp
원본 그림의 크기: 가로 193pixel, 세로 75pixel considers the zero-sequence currents as the sum and difference of two three-phase zero-sequence currents, as follows:

그림입니다.
원본 그림의 이름: CLP000027d80009.bmp
원본 그림의 크기: 가로 760pixel, 세로 112pixel     그림입니다.
원본 그림의 이름: CLP000027d8000a.bmp
원본 그림의 크기: 가로 512pixel, 세로 112pixel       (6)

For the S6-2N, the zero-sequence current cannot flow. Therefore, the 0+ and 0- currents can be neglected regardless of the choice of a transformation matrix. However, for the S6-1N, the zero-sequence currents can flow, depending on the choice of transformation matrix:

· For 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel, both the 0+ and 0- currents can flow. As a matter of fact, the two currents are not independent. However, they have equal magnitudes and opposite signs. Therefore:

그림입니다.
원본 그림의 이름: CLP000027d8000d.bmp
원본 그림의 크기: 가로 356pixel, 세로 76pixel          (7)

· For 그림입니다.
원본 그림의 이름: CLP000027d8000c.bmp
원본 그림의 크기: 가로 198pixel, 세로 74pixel, the 0+ current is zero, while the 0- current can flow.

From the way the 0+ and 0- currents are defined, it seems as though 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel is more suitable for the 2N configuration, while 그림입니다.
원본 그림의 이름: CLP000027d8000c.bmp
원본 그림의 크기: 가로 198pixel, 세로 74pixel is more suitable for the 1N configuration. In fact, for the S6-1N, it is obvious that choosing 그림입니다.
원본 그림의 이름: CLP000027d8000c.bmp
원본 그림의 크기: 가로 198pixel, 세로 74pixel over 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel reduces the number of required current controllers from 6 to 5, since i0+ does not need to be controlled. To date, this is the only apparent advantage of 그림입니다.
원본 그림의 이름: CLP000027d8000c.bmp
원본 그림의 크기: 가로 198pixel, 세로 74pixel over 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel found in the literature.

However, since 그림입니다.
원본 그림의 이름: CLP000027d8000e.bmp
원본 그림의 크기: 가로 293pixel, 세로 69pixel, as pointed out in (7), 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel permits the use of a single controller for one of the variables, while the other variable does not need to be specifically controlled. The number of independent controllers depends on the degrees of freedom, which should be constant and independent of the employed axis transformation.

It can be said that both transformations have been used interchangeably in the past, and the advantage of one over the other was not clearly discussed. This was the motivation for this work, which demonstrates that the two transformations give rise to different controller output voltages, which affects the maximum modulation limit. This in turn, affects the maximum motor speed during post-fault. Furthermore, the authors demonstrate that min-max injection, which is commonly regarded as useless for S6-1N machines, can help extend the maximum modulation limits in post-fault operations.

This paper is structured as follows. Section II describes the fault-tolerant control of a S6-1N using full-order transformation based on a dual synchronous reference frame PI current controller considering different common-mode voltage injections. Section III briefly demonstrates the implementation of min- max injection. Experimental results and discussions are given in Section IV. Finally, some conclusions are presented in Section V.



Ⅱ. REFERENCE VOLTAGE ISSUE IN FOT FAULT-TOLERANT CONTROL

The overall control structure of an FOT fault-tolerant drive for a S6-1N is shown in Fig. 1. For i = a1, b1, c1, a2, b2, c2, the phase voltage for phase-i of the machine vin is defined as the voltage of terminal-i with respect to the neutral point n. The inverter leg voltage 그림입니다.
원본 그림의 이름: CLP000027d8001f.bmp
원본 그림의 크기: 가로 69pixel, 세로 45pixel, on the other hand, is defined as the voltage of the machine terminal with respect to the DC-link midpoint 0.


그림입니다.
원본 그림의 이름: CLP000027d8001d.bmp
원본 그림의 크기: 가로 7798pixel, 세로 2116pixel

Fig. 1. Fault-tolerant control scheme with a single isolated neutral connection.


The rotor flux oriented control (RFOC) method based on SRF-PI and DSRF-PI controllers [21], as shown in Fig. 2, is used to make the machine stator currents follow the designated post-fault current references [2]. The controller generates reference voltages in the stationary reference frame (αβxy0+0-), which are then transformed into the phase reference voltages 그림입니다.
원본 그림의 이름: CLP000027d80011.bmp
원본 그림의 크기: 가로 754pixel, 세로 61pixel using an inverse decoupling transformation 그림입니다.
원본 그림의 이름: CLP000027d80010.bmp
원본 그림의 크기: 가로 113pixel, 세로 67pixel. Depending on the choice of 그림입니다.
원본 그림의 이름: CLP000027d8000f.bmp
원본 그림의 크기: 가로 88pixel, 세로 75pixel, slight modifications of the controllers become necessary. If 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel is used, one DSRF-PI controller is used to control the 0- current. Then the resulting control effort of the 0- current is multiplied by -1 to obtain the 0+ current. On the other hand, if 그림입니다.
원본 그림의 이름: CLP000027d80012.bmp
원본 그림의 크기: 가로 195pixel, 세로 72pixel is used, only one DSRF-PI controller is need for 0- current control, and 그림입니다.
원본 그림의 이름: CLP000027d80013.bmp
원본 그림의 크기: 가로 92pixel, 세로 72pixel can be set to zero to further simplified the controller. Using the carrier based PWM method, these phase voltage references are converted into modulation signals, which are then compared with triangular carrier signals to generate switching signals for the VSI. It is important to recognized that in the linear modulation region, with the control delay ignored, the PWM block and the inverter can be considered as a unity gain. Thus, the reference voltages, vi* become equal to the leg voltages vi0.


그림입니다.
원본 그림의 이름: CLP000027d8001c.bmp
원본 그림의 크기: 가로 3717pixel, 세로 3238pixel

Fig. 2. Fault-tolerant control scheme with DSRF (dual PI) controllers in the x-y current loop.


In the fault-tolerant control of an n-phase machine using the FOT approach, n-voltage references are generated even when one or more of the phases of the machine is open- circuited. Obviously, the reference voltages for the faulted phase(s) are not applied onto the machine. However, the overall control still provides all six reference voltages. As a result, there are multiple sets of possible voltage references that can be applied by the controller, which gives the same currents (hence operating points) for the machine.

To illustrate this scenario, experimental results from a S6-1N rig controlled using the FOT approach and shown in Fig. 1 and Fig. 2, are used for discussion here. Information on the experimental rig is given in the Appendix. The S6-1N machine was subjected to a single open circuit fault (1 OCF) so that phase-a1 is open-circuited. Then it was controlled to run at 800 rpm, with id = 1.3A and iq = 2.41A. Fig. 3 shows results obtained with the FOT control using 그림입니다. (right plot) and 그림입니다. (left plot).


Fig. 3. Test 1: 1 OCF at 800 rpm based on 그림입니다. (left plots) and 그림입니다. (right plots). From top to bottom. (a) Modulating signals. (b) Phase currents. (c) d-q currents.

그림입니다.
원본 그림의 이름: image3.png
원본 그림의 크기: 가로 781pixel, 세로 286pixel

그림입니다.
원본 그림의 이름: image4.png
원본 그림의 크기: 가로 783pixel, 세로 260pixel

(a)

 

 

그림입니다.
원본 그림의 이름: image5.png
원본 그림의 크기: 가로 781pixel, 세로 260pixel

그림입니다.
원본 그림의 이름: image6.png
원본 그림의 크기: 가로 783pixel, 세로 260pixel

(b)

 

 

그림입니다.
원본 그림의 이름: image7.png
원본 그림의 크기: 가로 781pixel, 세로 260pixel

그림입니다.
원본 그림의 이름: image8.png
원본 그림의 크기: 가로 783pixel, 세로 286pixel

(c)


As can be seen from these results, the reference voltages (which are analogous to the modulating signals) in Fig. 3(a) for the two control methods are significantly different. However, the post-fault currents are the same. It should be recalled that the reference voltage directly controls the inverter phase voltage and not the machine phase voltage. For the same phase currents, the phase voltages of the machine have to be the same for both cases. Hence, it can be deduced that there is a common-mode voltage that is present in the inverter leg voltages when one of the transformations is used.

To understand the concept of this common-mode voltage Vcm, each phase of the S6-1N machine can be represented as a Thevenin equivalent circuit, i.e. the EMF behind an RL- branch as shown in Fig. 1. For the purpose of discussion, it is assumed that 1 OCF occurs at phase-a1. 

Using Kirchoff’s voltage law, it is easy to see that (not including the faulted phase) the inverter leg voltage and the machine phase voltage of phase-i can be related by the following expression:

그림입니다.
원본 그림의 이름: CLP000027d80014.bmp
원본 그림의 크기: 가로 464pixel, 세로 71pixel            (8)

where 그림입니다.
원본 그림의 이름: CLP000027d8001e.bmp
원본 그림의 크기: 가로 98pixel, 세로 57pixel is the voltage of the neutral point with respect to the DC-link midpoint.

Hence, Vcm can be calculated using the following expression:

그림입니다.
원본 그림의 이름: CLP000027d80015.bmp
원본 그림의 크기: 가로 1382pixel, 세로 83pixel     (9)

Using (9) and the reference voltage signals in Fig. 3(a), the Vcm generated when using 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel and 그림입니다.
원본 그림의 이름: CLP000027d80012.bmp
원본 그림의 크기: 가로 195pixel, 세로 72pixel can be determined as shown in Fig. 4(a). As can be seen from this figure, an AC common-mode voltage is visible in the 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel approach. Meahwhile the 그림입니다.
원본 그림의 이름: CLP000027d80012.bmp
원본 그림의 크기: 가로 195pixel, 세로 72pixel approach has almost zero common-mode voltage.

Based on (8), the actual machine phase voltages can be obtained by subtracting Vcm from the inverter leg voltages (reference voltages) as shown in Fig. 4(b). The corresponding line-to-line voltages can then be determined, as shown in Fig. 4(c). As expected, the two approaches give the same machine phase and line voltages. Hence, the same currents and operating point.


Fig. 4. 1 OCF at 800 rpm based on 그림입니다. (left plots) and 그림입니다. (right plots). From top to bottom. (a) Common-mode signal, Vcm. (b) Phase voltages. (c) Line voltages.

그림입니다.
원본 그림의 이름: image9.png
원본 그림의 크기: 가로 781pixel, 세로 286pixel

그림입니다.
원본 그림의 이름: image10.png
원본 그림의 크기: 가로 783pixel, 세로 286pixel

(a)

 

그림입니다.
원본 그림의 이름: image11.png
원본 그림의 크기: 가로 781pixel, 세로 260pixel

그림입니다.
원본 그림의 이름: image12.png
원본 그림의 크기: 가로 783pixel, 세로 260pixel

(b)

 

그림입니다.
원본 그림의 이름: image13.png
원본 그림의 크기: 가로 781pixel, 세로 260pixel

그림입니다.
원본 그림의 이름: image14.png
원본 그림의 크기: 가로 783pixel, 세로 260pixel

(c)


Even though Vcm eventually gets cancelled out and the machine’s operating points are the same for the two approaches, the Vcm causes the 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel approach to have a higher modulating signal and it tends to go into premature over-modulation, which restricts the maximum operating region [25].

Therefore, some conclusions can be extracted from the analysis with regard to the common-mode voltage signal.

ⅰ. Control using different transformation matrices gives different common-mode voltage signals that result in different modulating signals.

ⅱ. The common-mode voltage signal is cancelled out in the phase voltages, so that there is no difference in the amplitude of the line voltage applied to the machine, provided that the modulating signals are within their linear limits.

These test and analysis results can be extended to OCF with up to three phases, and arrive at the same conclusions.



Ⅲ. MIN-MAX INJECTION IN FAULT-TOLERANT CONTROL

Based on the discussion in the previous section, the following deductions can be made:

ⅰ. There is a need to minimize the voltage references (hence the modulating signals) so that the linear modulation region can be maximized.

ⅱ. An additional common-mode signal, or zero- sequence signal can be freely added to all of the phase voltage references to modify the amplitude of the modulating signals without affecting the control outcome.

Hence, this paper proposes the use of min-max injection for S6-1N to maximize the linear modulation region. It should be noted that min-max injection is commonly used for 3-phase and even multiphase under healthy conditions to extend the linear modulation region. However, whether it is applicable to faulty conditions has never been discussed.

The min-max injection method essentially adds a common signal (i.e. zero-sequence signal) to all of the reference voltages (hence modulating signals) [25]. For PWM using the bipolar carrier, the zero-sequence signal to be added is given as:

그림입니다.
원본 그림의 이름: CLP000027d8001a.bmp
원본 그림의 크기: 가로 945pixel, 세로 71pixel      (10)

with i = a1, b1, c1, a2, b2, c2

From (9), (10) can be written in the general form as:

그림입니다.
원본 그림의 이름: CLP000027d8001b.bmp
원본 그림의 크기: 가로 1196pixel, 세로 170pixel        (11)

By subtracting this zero sequence signal from the reference voltages, Vcm is automatically removed as shown in equation (12) for phase Va1n.

그림입니다.
원본 그림의 이름: CLP000027d80019.bmp
원본 그림의 크기: 가로 1488pixel, 세로 539pixel     (12)

Furthermore, the modulating voltage signals are shifted to be symmetrical along the horizontal-axis, which results in a maximized modulation index. It is must be noted that min- max injection reduces the magnitude and yields the same modulating signals since it essentially reverts to the basic voltages that are required by the machine (phase voltages).



Ⅳ. RESULTS AND DISCUSSIONS

In order to verify the effectiveness of min-max injection in extending the maximum modulation limit for a post-fault S6-1N, experimental results for fault scenarios up to 3 OCFs were conducted. In the post-fault control, the flux current id is maintained at its rated value of 1.3A. Meanwhile, the torque current is reduced so that the maximum post-fault phase current is equal to the rated phase current of a 3.55A peak.

The motor speed was gradually increased until the maximum modulation limit was achieved (i.e. when the highest modulating signal(s) is equal to 1). Table I summarizes the post-fault torque and maximum achievable speed before and after min-max injection considering different fault scenarios. It should be highlighted that even though flux current id is maintained at its rated value, the post-fault torque current iq (hence post-fault torque T’) differs depending on the derating factor. Furthermore, since machine voltage under the faulted mode is dominated by the q-axis voltage, which depends on the flux-current (id) and not the torque current (iq) [26], the evaluation of the maximum speed is not significantly affected by different values of iq.


TABLE I  INDEPENDENT FAULT SCENARIOS FOR A SYMMETRICAL MACHINE CONSIDERING MIN-MAX INJECTION

Scenario

Faulty phase

Derating factor, a

id (A)

iq (A)

Torque derating (p.u)

Max Speed Without Min-Max Injection (RPM)

Max Speed With Min-Max Injection (RPM)

그림입니다.

그림입니다.

1

a1

0.771

1.3

2.41

0.73

1100

1500

1600

2a

a1- b1

0.577

1.3

1.58

0.48

800

1400

1700

2b

a1- a2

0.500

1.3

1.21

0.37

1700

1800

2000

2c

a1- b2

0.577

1.3

1.58

0.48

1400

1700

1750

3a

a1- b1- c1

0.500

1.3

1.21

0.37

800

1600

2250


As expected, the two approaches yielded different maximum speeds, with 그림입니다.
원본 그림의 이름: CLP000027d8000b.bmp
원본 그림의 크기: 가로 151pixel, 세로 76pixel having the lower speed limit due to the presence of Vcm. Nevertheless, with the min-max injection, the maximum attainable speeds for both methods became the same.

To further illustrate the impact of min-max injection, Fig. 5 shows a comparison of the maximum speed before and after injection. As can be seen from the figure, the use of min-max injection effectively reduces the amplitude of the modulating signals and extends the maximum modulation limit. Consequently, the machine can achieve a higher operable speed and yield a higher power in the post-fault mode, without violation of the voltage limit. It is worth noting that applying min-max injection to either of the transformation matrixes essentially results in the same modulating signals and maximum speeds.


Fig. 5. Comparison of the maximum achievable speed before and after min-max injection between 그림입니다. and 그림입니다. for: (a) 1 OCF. (b) 2 OCFs. (c) 3 OCFs.

그림입니다.
원본 그림의 이름: CLP000027d80016.bmp
원본 그림의 크기: 가로 822pixel, 세로 829pixel

(a)

그림입니다.
원본 그림의 이름: CLP000027d80017.bmp
원본 그림의 크기: 가로 965pixel, 세로 828pixel

(b)

그림입니다.
원본 그림의 이름: CLP000027d80018.bmp
원본 그림의 크기: 가로 1217pixel, 세로 824pixel

(c)


Fig. 6, Fig. 7 and Fig. 8 illustrate the modulating voltages, phase currents and common-mode voltages before and after min-max injection for 1 OCF, 2 OCFs and 3 OCFs, respectively. Based on Table I, since the power is the product of the torque and the speed, the maximum post-fault power of the machine is affected. For all of the cases, the use of min-max injection increases the maximum modulation index and the maximum post-fault operating speed.


Fig. 6. Test 1: 1 OCF with min-max injection at the rated speed based on 그림입니다. (left plots) and 그림입니다. (right plots). From top to bottom. (a) Modulating signals. (b) Phase currents. (c) Common-mode signal, Vcm. (d) Phase voltages. (e) Line voltages.

그림입니다.
원본 그림의 이름: image15.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image16.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(a)

그림입니다.
원본 그림의 이름: image17.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

그림입니다.
원본 그림의 이름: image18.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

(b)

그림입니다.
원본 그림의 이름: image19.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

그림입니다.
원본 그림의 이름: image20.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

(c)

그림입니다.
원본 그림의 이름: image21.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image22.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(d)

그림입니다.
원본 그림의 이름: image23.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image24.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(e)


Fig. 7. Test 1: 2 OCFs (scenario 2a) with min-max injection at the rated speed based on 그림입니다. (left plots) and 그림입니다. (right plots). From top to bottom. (a) Modulating signals. (b) Phase currents. (c) Common-mode signal, Vcm. (d) Phase voltages. (e) Line voltages.

그림입니다.
원본 그림의 이름: image25.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image26.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(a)

그림입니다.
원본 그림의 이름: image27.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

그림입니다.
원본 그림의 이름: image28.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

(b)

 

그림입니다.
원본 그림의 이름: image29.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

그림입니다.
원본 그림의 이름: image30.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

(c)

그림입니다.
원본 그림의 이름: image31.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image32.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(d)

그림입니다.
원본 그림의 이름: image33.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image34.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(e)


Fig. 8. Test 1: 3 OCFs (scenario 3a) with min-max injection at the rated speed based on 그림입니다. (left plots) and 그림입니다. (right plots). From top to bottom. (a) Modulating signals. (b) Phase currents. (c) Common-mode signal, Vcm. (d) Phase voltages. (e) Line voltages.

그림입니다.
원본 그림의 이름: image35.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image36.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(a)

그림입니다.
원본 그림의 이름: image37.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

그림입니다.
원본 그림의 이름: image38.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

(b)

그림입니다.
원본 그림의 이름: image39.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

그림입니다.
원본 그림의 이름: image40.png
원본 그림의 크기: 가로 783pixel, 세로 340pixel

(c)

그림입니다.
원본 그림의 이름: image41.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image42.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(d)

그림입니다.
원본 그림의 이름: image43.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

그림입니다.
원본 그림의 이름: image44.png
원본 그림의 크기: 가로 1366pixel, 세로 579pixel

(e)


As shown in [27], the ability to run above the base speed can be advantageous for post-fault operation since the additional increase in speed can compensate the low post-fault torque and increase the overall post-fault power. Furthermore, as predicted, once min-max injection is used, the maximum post- fault speeds of the machine using either of the transformations are the same.

The modulating index should be decided with respect to the line voltages. This means that if the line-to-line voltage is less than ±Vdc, there is no overmodulation issue. Fig. 9 shows the normalized line-to-line voltage at the maximum speed before and after min-max injection for 1 OCF with 1N based on the MT and ML modes, respectively. Referring to Fig. 9 and Table II, it can be seen that min-max injection can give a higher speed when compared to the MT and ML modes without using min-max injection. Furthermore, the value of the line-to-line voltage after min-max injection at the maximum speed is the same as that with the dc link voltage.


그림입니다.
원본 그림의 이름: image46.png
원본 그림의 크기: 가로 688pixel, 세로 344pixel

Fig. 9. Normalized line voltage amplitude at the maximum speed with and without min-max injection (mm) for 1 OCF based on Maximum Torque (MT) or Minimum Loss (ML) connected with a single isolated neutral (1N).


TABLE II  MAXIMUM LINE VOLTAGE BASED ON DIFFERENT OPERATING MODES AND NEUTRAL CONFIGURATIONS

Mode

Healthy

MT1N

ML1N

MT/ML 1N

Min-Max Injection

Without Min-Max Injection

With Min-Max Injection

Max Line Voltage (p.u)

1

0.6551

0.6449

1



Ⅴ. CONCLUSIONS

This paper investigated the effect of a post-fault control method for a S6-1N machine in terms of voltage and speed limit using min-max injection. It was demonstrated that the voltage limit has a direct impact on the speed limit. The line voltage amplitude, on the other hand, depends on the zero sequence components. Although both transformations can effectively control the machine in the post-fault mode, they yield different modulating signals. As a result, they have different maximum speed limits. When comparing the two transformations, 그림입니다.
원본 그림의 이름: CLP000027d80012.bmp
원본 그림의 크기: 가로 195pixel, 세로 72pixel is found to be better in terms of the number of current controllers required and the maximum modulation limit. It was further demonstrated that min-max injection can be utilized to improve the post-fault performance of a S6-1N machine. The use of min-max injection maximizes the modulation limit and post-fault speed of the machine, giving overall better post-fault power.



APPENDIX


TEST RIG

The experimental results presented in this paper were obtained using a S6 machine. The S6 machine was obtained by rewinding a 0.55 kW three-phase induction machine. The general layout for the test rig is shown in Fig. 10. In the test rig, the S6-IM is driven by two three-phase two-level voltage source converters composed of Semikron SKM75GB12T4 modules that correspond to VSC1 and VSC2. The converters are connected to a DC power supply and the control is implemented via a dSPACE DS1103 rapid prototyping system. Speed and current measurements are taken with an E60H20- 5000-3-N-5 digital encoder and LEM LTSR-15-NP hall-effect sensors, respectively. The load torque was applied by a permanent magnet generator connected to a variable resistive- inductive load. The OCFs were created by physically disconnecting the inverter from the motor phases using relays.


그림입니다.
원본 그림의 이름: image48.jpeg
원본 그림의 크기: 가로 992pixel, 세로 663pixel

Fig. 10.  Test-rig: S6-IM used for experimentation.


TABLE III  INDUCTION MOTOR RATED VALUES AND MACHINE PARAMETERS

Rated Frequency

50 Hz

Rated Phase Voltage

120 Vrms

Rated Phase Current

1.45 Arms

Rated Mechanical Speed

1390 rpm

Stator Resistance

Rs = 12.85 Ω

Rotor Resistance

Rr = 6.5 Ω

Magnetizing Inductance

Lm= 0.42 H

Stator Leakage Inductance

Lls= 0.0060 H

Rotor Leakage Inductance

Llr= 0.08 H

Stator Leakage Inductance (x-y)

Lls xy = 0.0063 H

Stator Leakage Inductance (0+0-)

Lls 0+0- = 0.03 H



ACKNOWLEDGMENT

The authors would like to acknowledge the support from the Malaysian government through the Malaysian Ministry of Higher Education (MOHE) under project number MO013- 2016 and the Universiti Teknologi MARA (UiTM).



REFERENCES

[1] F. Barrero and M. J. Duran, “Recent advances in the design, modeling, and control of multiphase machines - Part I,” IEEE Trans. Ind. Electron., Vol. 63, No. 1, pp. 449-458, Jan. 2016.

[2] W. N. W. A. Munim, M. Duran, H. S. Che, M. Bermudez, I. Gonzalez-Prieto, and N. Abd Rahim, “A unified analysis of the fault tolerance capability in six-phase induction motor drive,” IEEE Trans. Power Electron., Vol. 32, No. 10, pp. 7824-7836, Oct. 2017.

[3] H. Guzman, M. J. Duran, F. Barrero, L. Zarri, B. Bogado, I. Gonzalez Prieto, and M. R. Arahal, “Comparative study of predictive and resonant controllers in fault-tolerant five- phase induction motor drives,” IEEE Trans. Ind. Electron., Vol. 63, No. 1, pp. 606-617, Jan. 2016.

[4] H. Guzman, M. J. Duran, F. Barrero, B. Bogado, and S. Toral, “Speed control of five-phase induction motors with integrated open-phase fault operation using model-based predictive current control techniques,” IEEE Trans. Ind. Electron., Vol. 61, No. 9, pp. 4474-4484, Sep. 2014.

[5] A. S. Abdel-Khalik, S. Ahmed, A. A. Elserougi, and A. M. Massoud, “Effect of stator winding connection of five- phase induction machines on torque ripples under open line condition,” IEE/ASME Trans. Mechatron., Vol. 20, No. 2, pp. 580–593, Apr. 2015.

[6] A. S. Abdel-Khalik, M. A. Elgenedy, S. Ahmed, and A. M. Massoud, “An improved fault tolerant five-phase induction machine using a combined star/pentagon single layer stator winding connection,” IEEE Trans. Ind. Electron., Vol. 63, No. 1, pp. 618-628, Jan. 2016.

[7] M.-A. Shamsi-Nejad, B. Nahid-Mobarakeh, S. Pierfederici, and F. Meibody-Tabar, “Fault tolerant and minimum loss control of double-star synchronous machines under open phase conditions,” IEEE Trans. Ind. Electron., Vol. 55, No. 5, pp. 1956-1965, May 2008.

[8] R. Kianinezhad, B. Nahid-Mobarakeh, L. Baghli, F. Betin, and G.-A. Capolino, “Modeling and control of six-phase symmetrical induction machine under fault condition due to open phases,” IEEE Trans. Ind. Electron., Vol. 55, No. 5, pp. 1966-1977, May 2008.

[9] F. Baudart, B. Dehez, E. Matagne, D. Telteu-nedelcu, P. Alexandre, and F. Labrique, “Torque control strategy of polyphase permanent-magnet synchronous machines with minimal controller reconfiguration under open-circuit fault of one phase,” IEEE Trans. Ind. Electron., Vol. 59, No. 6, pp. 2632-2644, Jun. 2012.

[10] A. Pantea, A. Yazidi, F. Betin, M. Taherzadeh, S. Carrière, H. Henao, and G. A. Capolino, “Six-phase induction machine model for electrical fault simulation using the circuit-oriented method,” IEEE Trans. Ind. Electron., Vol. 63, No. 1, pp. 494-503, Jan. 2016.

[11] M. Duran, I. Gonzalez, M. Bermudez, F. Barrero, H. Guzman, and M. Arahal, “Optimal fault-tolerant control of six-phase induction motor drives with parallel converters,” IEEE Trans. Ind. Electron., Vol. 63, No. 1, pp. 629-640, Jan. 2016.

[12] I. Gonzalez-Prieto, M. J. Duran, H. S. Che, E. Levi, M. Bermúdez, and F. Barrero, “Fault-tolerant operation of six- phase energy conversion systems with parallel machine- side converters,” IEEE Trans. Power Electron., Vol. 31, No. 4, pp. 3068-3079, Apr. 2016.

[13] M. Tousizadeh, H. S. Che, J. Selvaraj, N. A. Rahim, and B. T. Ooi, “Fault-tolerant field oriented control of three-phase induction motor based on unified feed-forward method,” IEEE Trans. Power Electron., to be published. doi:10.1109/ TPEL.2018.2884759

[14] Y. Zhao and T. A. Lipo, “Modeling and control of a multi- phase induction machine with structural unbalance - Part I,” IEEE Trans. Energy Convers., Vol. 11, No. 3, pp. 570-577, Sep. 1996.

[15] Y. Zhao and T. A. Lipo, “Modeling and control of a multi-phase induction machine with structural unbalance - Part II,” IEEE Trans. Energy Convers., Vol. 11, No. 3, pp. 578-584, Sep. 1996.

[16] H. Ryu, J. Kim, and S. Sul, “synchronous-frame current control of multiphase synchronous motor under asymmetric fault condition due to open Phases,” IEEE Trans. Ind. Appl., Vol. 42, No. 4, pp. 1062-1070, Jul./Aug. 2006.

[17] H. Zhou, W. Zhao, G. Liu, R. Cheng, and Y. Xie, “Remedial field-oriented control of five-phase fault-tolerant permanent- magnet motor by using reduced-order transformation matrices,” IEEE Trans. Ind. Electron., Vol. 64, No. 1, pp. 169-178, Jan. 2017.

[18] F. Locment, E. Semail, and X. Kestelyn, “Vectorial approach- based control of a seven-phase axial flux machine designed for fault operation,” IEEE Trans. Ind. Electron., Vol. 55, No. 10, pp. 3682-3691, Oct. 2008.

[19] A. Tani, M. Mengoni, L. Zarri, G. Serra, and D. Casadei, “Control of multiphase induction motors with an odd number of phases under open-circuit phase faults,” IEEE Trans. Power Electron., Vol. 27, No. 2, pp. 565-577, Feb. 2012.

[20] H. S. Che, E. Levi, M. Jones, W. Hew, and N. A. Rahim, “Current control methods for an asymmetrical six-phase induction motor drive,” IEEE Trans. Power Electron. Trans. Power Electron., Vol. 29, No. 1, pp. 407-417, Jan. 2014.

[21] H. S. Che, M. J. Duran, E. Levi, M. Jones, W. Hew, and N. A. Rahim, “Postfault operation of an asymmetrical six-phase induction machine with single and two isolated neutral points,” IEEE Trans. Power Electron., Vol. 29, No. 10, pp. 5406-5416, Oct. 2014.

[22] D. G. Holmes, B. P. Mcgrath, and S. G. Parker, “Current regulation strategies for vector-controlled induction motor drives,” IEEE Trans. Ind. Electron., Vol. 59, No. 10, pp. 3680-3689, Oct. 2012.

[23] I. Gonzalez-Prieto, M. J. Duran, and F. J. Barrero, “Fault-tolerant control of six-phase induction motor drives with variable current injection,” IEEE Trans. Power Electron., Vol. 32, No. 10, pp. 7894-7903, Oct. 2017.

[24] F. Baneira, J. Doval-Gandoy, A. G. Yepes, O. Lopez, and D. Perez-Estevez, “Control strategy for multiphase drives with minimum losses in the full torque operation range under single open-phase fault,” Vol. 32, No. 8, pp. 6275-6285, Aug. 2017.

[25] A. S. Abdel-khalik, A. M. Massoud, and S. Ahmed, “Effect of dc-link voltage limitation on postfault steady-state performance of asymmetrical six- phase induction machines,” IEEE Trans. Ind. Electron., Vol. 65, No. 9, pp. 6890-6900, Sept. 2018.

[26] M. Tousizadeh, H. S. Che, N. Abd Rahim, J. Selvaraj, and B. T. Ooi, “Performance comparison of fault-tolerant three- phase induction motor drives considering current and voltage limits,” IEEE Trans. Ind. Electron., Vol. 66, No. 4, pp. 2639-2648, Apr. 2019.

[27] O. Fall, N. Ky, J. Frédéric, P. Letellier, E. Semail, and X. Kestelyn, “Variable speed control of a 5-phase permanent magnet synchronous generator including voltage and current limits in healthy and open-circuited modes,” Electr. Power Syst. Res., Vol. 140, pp. 507-516, Jun. 2016.



그림입니다.
원본 그림의 이름: image49.jpeg
원본 그림의 크기: 가로 190pixel, 세로 225pixel

Wan Noraishah Wan Abdul Munim received her Diploma in Electrical Engineering (Communications) from the University Teknologi Malaysia, Skudai, Malaysia, in 2003; her B.S. degree in Electrical Engineering from the Universiti Kuala Lumpur, Kuala Lumpur, Malaysia, in 2007; and her M.S. degree in Electrical Power Engineering with Business from the University of Strathclyde, Glasgow, SCT, UK, in 2009. She is presently working towards her Ph.D. degree in Electrical Engineering at the UM Power Energy Dedicated Advanced Centre, University of Malaya, Kuala Lumpur. Since 2010, she has been working as a Senior Lecturer at the Universiti Teknologi MARA, Shah Alam, Malaysia. Her current research interests include multiphase machines and drives, fault-tolerant control, and renewable energy. Ms. Munim received a 2014 Ministry of Education Malaysia Skim Latihan Akademik IPTA (SLAI) Scholarship Award for her Ph.D. studies.


그림입니다.
원본 그림의 이름: image50.jpeg
원본 그림의 크기: 가로 191pixel, 세로 239pixel

Mahdi Tousizadeh received his B.S. degree in Electrical Engineering from Islamic Azad University, Isfahan, Iran, in 2009; his M.S. degree in Electrical Engineering-Mechatronics and Automatic Control from the University Technology Malaysia, Skudai, Malaysia, in 2012; and his Ph.D. degree in Power Electronics Motor Drives from the University of Malaya, Kuala Lumpur, Malaysia, in 2019. Dr. Mahdi has been a researcher at the UM Power Dedicated Advanced Center since 2013. His current research interests include the fault- tolerant control of machines and drives, with a focus on induction and switch reluctance motor drives, and power electronics converters for electric vehicle applications.


그림입니다.
원본 그림의 이름: image51.jpeg
원본 그림의 크기: 가로 219pixel, 세로 280pixel

Hang Seng Che received his B.S. degree in Electrical Engineering from the University of Malaya, Kuala Lumpur, Malaysia, in 2009; and his Ph.D. degree in Electrical Engineering under the auspices of a dual Ph.D. program between the University of Malaya and Liverpool John Moores University, Liverpool, ENG, UK, in 2013. Since 2013, he has been working at the UM Power Energy Dedicated Advanced Centre, University of Malaya, where he is presently a Senior Lecturer. Dr. Che has been an Associate Editor for the IET Electric Power Applications journal since 2016. His current research interests include multiphase machines and drives, fault-tolerant control, and power electronics converters for renewable energy applications. He received a 2009 Kuok Foundation Postgraduate Scholarship Award for his Ph.D. studies.