Three-Phase Common-Mode Active EMI Filters for Induction Motor Drive Applications


Vuttipon Tarateeraseth


Department of Electrical Engineering, Srinakharinwirot University, Nakhonnayok, Thailand



Abstract

In this paper, the conducted EMI reduction performances of active feed-forward current-sensing current-actuation (CSCA) and voltage-sensing current-actuation (VSCA) filters for a three-phase induction motor drive system are evaluated by experiments. For comparison purposes, the conducted EMI (CM emission, DM emission and total emission) of a three-phase induction motor drive with a conventional CM choke, a conventional CM choke in series with an active VSCA filter, and an active CSCA filter (where the CM choke was modified and used as a sensing current transformer) were compared to the case of a system without any filter inserted. Experimental results show that the active CSCA and VSCA filters can improve the CM reduction performance of the conventional CM choke by about 5 dB especially at low-frequencies. However, for DM comparisons, it shows that there is no different between cases with and without filters inserted.


Key words: Active CSCA filter, Active VSCA filter, Common-mode active EMI filter, Induction motor drives, Tree-phase common-mode choke


Manuscript received Sep. 5, 2017; accepted Jan. 11, 2018

Recommended for publication by Associate Editor Trillion Q Zheng.

Corresponding Author: vuttipon@g.swu.ac.th Tel: +66-80-5650072, Srinakharinwirot University

Dept. of Electrical Engineering, Srinakharinwirot University, Thailand



Ⅰ. INTRODUCTION

Nowadays, modern power converters are being embedded into various applications because of their significant advantages such as high power conversion efficiency, cost and compact physical size [1]. The ultra-fast switching behavior of modern power converters can cause electromagnetic interference (EMI), while it is generally known that the failure/ malfunction of all electronic devices, equipment or systems is caused by EMI [2]. To eliminate EMI, passive or active EMI filters are generally installed between the power electronic converters and the grid [3]. However, in order to prevent bearing failures and severe vibrations in motor drive applications, common-mode (CM) noise must be eliminated [6]. Many methods have been proposed to suppress the CM emissions in the three-phase motor drive applications, i.e. modulation techniques [4], [5], multi-level multi-phase inverters [6]-[8] and active/hybrid filtering techniques [9]- [11]. However, these methods need to introduce a complicated design procedure or complex external circuits.

As a result, for three-phase power converters, especially those for induction motor drive applications, passive EMI filters are widely used [12]-[14]. A CM choke is widely used because it is the simplest way to reduce CM emissions. However, a CM choke consumes up to 25% of the motor drive system volume [4]. Thus, to reduce the total size and weight, the CM inductance of a CM choke must be designed to be as small as possible by introducing CY where its value is limited by safety standards. To overcome these problems, an active-filter circuit is applied in series with the conventional CM choke to reduce low-frequency CM emissions [15]-[18]. Active-filter circuits can be categorized into 4 main types [15]. Recently, feed-forward current- sensing current-actuation (CSCA) [16], [17] and feed-forward voltage-sensing current-actuation (VSCA) [15] filters have been popularly used because it has been proved that current-canceling schemes are the most effective for high-impedance CM noise reductions [18].

However, it is necessary to determine how much CM noise can be reduced by adding two popular active-filters when compared to the case of adding a conventional CM choke, which is the aim of this paper.



Ⅱ. OPERATION OF A THREE-PHASE COMMON-MODE CHOKE

Conventionally, to limit CM currents in three-phase motor drive applications, a three-phase common-mode choke is used. A three-phase common-mode (CM) choke is composed of three windings with an equal number of turns, where the three windings are wound in the same direction and placed in parallel. The three windings are connected specifically between three line wires i.e. L1, L2, and L3.


Fig. 1. Three-phase CM choke under: (a) CM current; (b) DM current.

그림입니다.
원본 그림의 이름: image1.png
원본 그림의 크기: 가로 769pixel, 세로 321pixel

(a)

그림입니다.
원본 그림의 이름: image2.png
원본 그림의 크기: 가로 710pixel, 세로 305pixel

(b)


Fig. 1(a) and 1(b) show an equivalent circuit and the operational mechanisms of a three-phase CM choke while CM and DM currents pass through it, respectively. It can be concluded that when CM currents pass through it, mutual flux is accumulated. Thus, a huge amount of CM inductance is obtained, where the CM inductance can be defined by [19]:

그림입니다.
원본 그림의 이름: CLP00001478001c.bmp
원본 그림의 크기: 가로 919pixel, 세로 208pixel    (1)

Eq. (1) shows that the CM inductance is dependent on the operational frequency, inductance per turn (그림입니다.
원본 그림의 이름: CLP000022640011.bmp
원본 그림의 크기: 가로 77pixel, 세로 79pixel), number of turns (그림입니다.
원본 그림의 이름: CLP000022640012.bmp
원본 그림의 크기: 가로 75pixel, 세로 60pixel), and permeability (both the real part (그림입니다.
원본 그림의 이름: CLP000022640013.bmp
원본 그림의 크기: 가로 64pixel, 세로 66pixel) and the complex permeability 그림입니다.
원본 그림의 이름: CLP00001478001e.bmp
원본 그림의 크기: 가로 132pixel, 세로 81pixel. Moreover, high permeability materials such as a ferrite core must be chosen and proper winding techniques should be applied in order to reduce the parasitic elements.

When DM currents pass through a CM choke, the mutual flux is canceled. However, the leakage fluxes across each of the windings still exist, which generates a small amount of leakage inductance. Although the leakage inductance increases the power loss, it can moderately eliminate DM currents. Theoretically, the DM inductance of a toroidal three-phase CM choke can be estimated by [19]:

그림입니다.
원본 그림의 이름: CLP00001478001f.bmp
원본 그림의 크기: 가로 1061pixel, 세로 245pixel         (2)

그림입니다.
원본 그림의 이름: CLP000014780020.bmp
원본 그림의 크기: 가로 693pixel, 세로 182pixel   (3)

where 그림입니다.
원본 그림의 이름: CLP00002264000f.bmp
원본 그림의 크기: 가로 42pixel, 세로 52pixel is the winding angle (valid for 그림입니다.
원본 그림의 이름: CLP00002264000d.bmp
원본 그림의 크기: 가로 216pixel, 세로 72pixel), 그림입니다.
원본 그림의 이름: CLP00002264000e.bmp
원본 그림의 크기: 가로 67pixel, 세로 61pixel is the effective cross-sectional area, and 그림입니다.
원본 그림의 이름: CLP000022640010.bmp
원본 그림의 크기: 가로 45pixel, 세로 64pixel is the effective mean length of the core. To prevent core saturation due to DM currents, Eq. (4) must be satisfied.

그림입니다.
원본 그림의 이름: CLP000014780021.bmp
원본 그림의 크기: 가로 461pixel, 세로 199pixel   (4)

where그림입니다.
원본 그림의 이름: CLP00002264000c.bmp
원본 그림의 크기: 가로 93pixel, 세로 82pixel is the saturation flux of the chosen toroidal magnetic core. The CM inductance and leakage inductance of a three-phase CM choke can be measured. To measure the leakage inductance, two windings must be shorted while the left winding is measured for its leakage inductance. On the other hand, the CM inductance can be measured using an asymmetrical test circuit [20].


Fig. 2. Three-phase induction motor drive with a conventional CM choke: (a) Schematic; (b) CM equivalent circuit.

그림입니다.
원본 그림의 이름: image7.png
원본 그림의 크기: 가로 708pixel, 세로 212pixel

(a)

그림입니다.
원본 그림의 이름: image8.png
원본 그림의 크기: 가로 655pixel, 세로 362pixel

(b)


Fig. 2(a) and 2(b) show a schematic and a CM equivalent circuit of a three-phase induction motor drive with a conventional CM choke, respectively. According to Fig. 2 (b), the insertion loss of a three-phase induction motor drive with a conventional CM choke is derived as follows:

그림입니다.
원본 그림의 이름: CLP000014780022.bmp
원본 그림의 크기: 가로 655pixel, 세로 197pixel     (5)

where 그림입니다.
원본 그림의 이름: CLP000022640009.bmp
원본 그림의 크기: 가로 73pixel, 세로 75pixel is the noise source impedance, 그림입니다.
원본 그림의 이름: CLP00002264000a.bmp
원본 그림의 크기: 가로 48pixel, 세로 61pixel is the CM impedance of the line impedance stabilization network (LISN), and 그림입니다.
원본 그림의 이름: CLP00002264000b.bmp
원본 그림의 크기: 가로 73pixel, 세로 54pixel is the CM inductance of a conventional CM choke.



Ⅲ. OPERATION OF CM ACTIVE EMI FILTERS

According to the literature review in [15], the active-filter circuits used in power electronic systems can be categorized into the following 4 main types:

- Voltage-sensing current-actuation (VSCA) filter

- Voltage-sensing voltage-actuation (VSVA) filter

- Current-sensing current-actuation (CSCA) filter

- Current-sensing voltage-actuation (CSVA) filter

However, recently, feed-forward current-sensing current- actuation (CSCA) [16], [17] and feed-forward voltage- sensing current-actuation (VSCA) [15] have become the most widely recommended [18]. Thus, only CSCA and VSCA filters are discussed in this paper.


A. Current-Sensing Current-Actuation (CSCA) Filters

This type of active-filter circuit was proposed and implemented in [16], [17]. The main principle of this method is to boost the input impedance of a power electronic system with an active multiplication method using a proposed active-filter circuit. By introducing this proposed active-filter circuit in parallel with a power electronic system, the input impedance of the system can be boosted by a factor of the current gain of the CSCA filter. As a result, a larger current gain provides a better CM noise reduction performance.

The insertion loss of the system with an active multiplication method can be derived as [16]:

그림입니다.
원본 그림의 이름: CLP000014780023.bmp
원본 그림의 크기: 가로 1109pixel, 세로 222pixel       (6)

where A is the open-loop gain of an op-amp. As shown in Eq. (6), by adding an active-filter circuit, the input impedance of the system can be boosted by a factor of 그림입니다.
원본 그림의 이름: CLP000022640373.bmp
원본 그림의 크기: 가로 586pixel, 세로 83pixel.

However, the active-filter circuit proposed in [16] is only implemented for a single-phase power electronic system. With an active multiplication method, the CSCA filter for a three-phase motor drive system is modified and proposed as shown in Fig. 3.


Fig. 3. Proposed active CSCA filter for a three-phase induction motor drive: (a) Schematic; (b) Equivalent circuit of the proposed system.

그림입니다.
원본 그림의 이름: image18.png
원본 그림의 크기: 가로 721pixel, 세로 280pixel

(a)

그림입니다.
원본 그림의 이름: image19.png
원본 그림의 크기: 가로 619pixel, 세로 330pixel

(b)


B. Voltage-Sensing Current-Actuation (VSCA) Filter

The VSCA filter circuit was proposed and implemented in [15]. This topology uses a Y-capacitor to sense the line voltage, and it uses the actuator stage in order to cancel the CM noise current. Ideally, the Y-capacitor value should be chosen as large as possible to minimize the size of the CM choke. However, the Y-capacitor value is limited by safety standards. The main concept of this method is to virtually boost the capacitance of the existing 그림입니다.
원본 그림의 이름: CLP000022640001.bmp
원본 그림의 크기: 가로 71pixel, 세로 76pixel value by controlling the feedback-frequency response. Thus, the size of the CM choke can be reduced.

The basic principle of this topology is to boost the equivalent capacitance at a high frequency using proper shaping of the feedback loop as shown in Eq. (7)

그림입니다.
원본 그림의 이름: CLP000014780024.bmp
원본 그림의 크기: 가로 710pixel, 세로 164pixel         (7)

Eq. (7) shows that the capacitance can be virtually boosted by the factor of the gain 그림입니다.
원본 그림의 이름: CLP000022640002.bmp
원본 그림의 크기: 가로 139pixel, 세로 83pixel at high frequencies. This characteristic is remarkable since the capacitance value of the Y-capacitor at a low frequency can be kept below safety standards. The VSCA filter circuit is modified and proposed, as shown in Fig. 5, where it is composed of a CM choke (그림입니다.
원본 그림의 이름: CLP000022640006.bmp
원본 그림의 크기: 가로 97pixel, 세로 64pixel), a coupling capacitor (그림입니다.
원본 그림의 이름: CLP000022640005.bmp
원본 그림의 크기: 가로 59pixel, 세로 60pixel), a coupling resistor (그림입니다.
원본 그림의 이름: CLP000022640004.bmp
원본 그림의 크기: 가로 59pixel, 세로 62pixel), a sensing capacitor (그림입니다.
원본 그림의 이름: CLP000022640003.bmp
원본 그림의 크기: 가로 130pixel, 세로 64pixel), and an inverting amplifier circuit. According to Fig. 5 (b), the insertion loss of the proposed system can be derived as [23]:

그림입니다.
원본 그림의 이름: CLP000014780025.bmp
원본 그림의 크기: 가로 1387pixel, 세로 189pixel    (8)



Ⅳ. EXPERIMENTAL VALIDATIONS AND DISCUSSIONS

The aim of this paper is to determine how much CM noise can be reduced by adding two popular active-filters when compared to the case of adding only a conventional CM choke. Thus, the EMI reduction performance of a three-phase induction motor drive: with the conventional CM choke, the conventional CM choke in series with an active VSCA filter, and an active CSCA filter were verified by experiments. All of the cases used a CM choke. Therefore, for the sake of a fair comparison, identical CM chokes, where the CM inductance was equal to 3.5 mH, were used in all cases. However, it should be noted that only the case of the active CSCA filter the CM choke was used as the sensing current transformer.


A. Selected Components of the Three-Phase CM Choke Prototype

Fig. 4(a) shows the CM choke used in the experiments. The CM inductance (그림입니다.
원본 그림의 이름: CLP000022640006.bmp
원본 그림의 크기: 가로 97pixel, 세로 64pixel) is 3.5 mH. The designed parameters are: toroidal ferrite core (Vacuumschmelze# T60006-L2080-V091) with an outside diameter of 86 mm, number of turns = 15, copper size = AWG#18, and space between windings = 20 degree. It should be noted that, as shown in Fig. 4(a), there are four windings in the same core. However, in this case one winding is left open.


Fig. 4. Implementation of proposed filter circuits for a three- phase induction motor drive; (a) With conventional CM choke; (b) With active CSCA filter (modified CM choke used as sensing current transformer); (c) With CM choke in series with active VSCA filter.

그림입니다.
원본 그림의 이름: image22.png
원본 그림의 크기: 가로 700pixel, 세로 381pixel

(a)

그림입니다.
원본 그림의 이름: image23.png
원본 그림의 크기: 가로 707pixel, 세로 381pixel

(b)

그림입니다.
원본 그림의 이름: image24.png
원본 그림의 크기: 가로 706pixel, 세로 353pixel

(c)


Fig. 5. Proposed active VSCA filter for three-phase induction motor drives: (a) Schematic; (b) Equivalent circuit of the proposed system.

그림입니다.
원본 그림의 이름: image26.png
원본 그림의 크기: 가로 706pixel, 세로 260pixel

(a)

그림입니다.
원본 그림의 이름: image27.png
원본 그림의 크기: 가로 624pixel, 세로 331pixel

(b)


B. Selected Components of the Active CSCA Filter Prototype

For the active CSCA filter, the selected components were designed as shown in Table I [16], [17], [24], [25]. It should be noted that, as shown in Fig. 4(b), there are four windings in the same core acting as a current transformer (그림입니다.
원본 그림의 이름: CLP000022640007.bmp
원본 그림의 크기: 가로 116pixel, 세로 64pixel). There is no significant difference between the current transformer and the CM choke except for the number of windings. As a result, in this experiment, the CM choke shown in Fig. 4(a) was used. However, in this case one winding was connected to the inverting amplifier as shown in Fig. 4(b). Moreover, to maximize the op-amp’s gain, it is recommended to use a 그림입니다.
원본 그림의 이름: CLP000022640014.bmp
원본 그림의 크기: 가로 68pixel, 세로 69pixel of about 10 pF [16].


TABLE I SELECTED COMPONENTS FOR THE ACTIVE CSCA FILTER PROTOTYPE

Component

Specification

Op-amp

Texas Instruments: OPA847

CTCMCCCCCC

Vacuumschmelze# T60006-L2080-V091 N = 4x15 turns, AWG#18, 3.5 mH

RRR1 , R2 , R3 , Rf

5.6 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel

RR0

1 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel and 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel

Cf

Ceramic capacitor, 10 pF

Co

Y-capacitor, 3x10 nF


C. Selected Components of the Active VSCA Filter Prototype

For the active VSCA filter, selected components were designed as shown in Table II [15], [16], [24], [25]. It should be noted that in order to prevent the op-amp saturation caused by low-frequency components (50/60 Hz), the mentioned components must be attenuated in a feedback loop.


TABLE II SELECTED COMPONENTS FOR THE ACTIVE VSCA FILTER PROTOTYPE

Component

Specification

Op-amp

Texas Instruments: OPA847

Lcm

Vacuumschmelze# T60006-L2080-V091 N = 3x15 turns, AWG#18, 3.5 mH

Csense

Ceramic capacitor, 3x 1 nF

R1 , R2

5.6 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel

R0

1 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel and 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel

Co

Y-capacitor, 3x10 nF


D. Experimental Setup

The measurement setup and a testing block diagram of the experiment are shown in Fig. 6(a) and 6(b), respectively. The noise source is an induction motor drive (a three-phase inverter: ABB#ACS350 and a three-phase induction motor: ABB#M2QA100L4B, 3 kW). The noise source was powered through a three-phase line impedance stabilization network (LISN) including a CM and DM noise separator network [21], [22]. Referring to the CISPR 16 standard, the conducted EMI is measured through an EMC spectrum analyser (Agilent Spectrum Analyser: N9320B) with the frequency range of interest going from 150 kHz up to 30 MHz and BW at 9 kHz. Moreover, all of the equipment was installed on the metal ground reference plane.


Fig. 6. Depictions of: (a) EMI measurement setup; (b) Testing block diagram.

그림입니다.
원본 그림의 이름: image28.emf
원본 그림의 크기: 가로 1957pixel, 세로 695pixel

(a)

그림입니다.
원본 그림의 이름: image29.png
원본 그림의 크기: 가로 706pixel, 세로 342pixel

(b)


For comparison purposes, the conducted EMI (CM emission, DM emission, and total emission) of a three-phase induction motor drive: with the designed CM choke, the designed CM choke including an active VSCA filter, and an active CSCA filter (where the CM choke was modified and used as a sensing current transformer) were measured and compared.


E. Experimental Results and Discussions

To verify the conducted EMI reduction performance of the designed active VSCA and CSCA filters, three tests were conducted as follows:


1) Induction Motor Operating at 500 rpm

The measured conducted EMI of a three-phase induction motor drive without a filter was compared to the cases of one with the designed CM choke, with the designed CM choke including an active VSCA filter, and with an active CSCA filter (where the designed CM choke is used as a current transformer). Figs. 7(a)-(d) show conducted EMI comparisons in terms of CM and DM emissions, while Fig. 8(a)-(c) show conducted EMI comparisons at the line-to-ground and neutral-to-ground.


Fig. 7. Comparisons of the conducted EMI of an induction motor drive (operating at 500 rpm): without a filter, with the conventional CM choke, with a CSCA filter (R0 = 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel), and with a VSCA filter (R0 = 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel). (a) CM; (b) DM1; (c) DM2; (d) DM3.

그림입니다.
원본 그림의 이름: image49.png
원본 그림의 크기: 가로 693pixel, 세로 416pixel

(a)

그림입니다.
원본 그림의 이름: image50.png
원본 그림의 크기: 가로 693pixel, 세로 416pixel

(b)

그림입니다.
원본 그림의 이름: image51.png
원본 그림의 크기: 가로 693pixel, 세로 407pixel

(c)

그림입니다.
원본 그림의 이름: image52.png
원본 그림의 크기: 가로 693pixel, 세로 407pixel

(d)


Fig. 8. Comparisons of the conducted EMI of an induction motor drive (operating at 500 rpm): without a filter, with the conventional CM choke, with a CSCA filter (R0 = 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel), and with a VSCA filter (R0 = 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel). (a) L1-to-ground; (b) L2-to-ground; (c) L3-to-ground.

그림입니다.
원본 그림의 이름: image53.png
원본 그림의 크기: 가로 722pixel, 세로 398pixel

(a)

그림입니다.
원본 그림의 이름: image54.png
원본 그림의 크기: 가로 722pixel, 세로 408pixel

(b)

그림입니다.
원본 그림의 이름: image55.png
원본 그림의 크기: 가로 720pixel, 세로 412pixel

(c)


It is obvious that the CM noise was dramatically reduced when a filter was applied when compared to the case of the noise source without any filter inserted as shown in Fig. 7 (a). Moreover, a CM attenuation of about -5 dB was gained when introducing active CSCA and VSCA filters. This was especially true at low-frequencies. However, for DM comparisons, it shows similar results in all of the cases as shown in Fig. 7(b)-(d).

For the measured total noises at the line-to-ground and neutral-to-ground, comparison results are shown in Fig. 8(a)-(c). It can be seen that when the proposed filters were inserted, the total noises were dramatically reduced when compared to the case of a noise source without any filter inserted. The total noises can be suppressed up to 25 dB.

Similarly, a noise source with CSCA and VSCA filters especially at a low-frequency can be improved by about 5 dB when comparing to the case of that with only a CM choke.


2) Induction Motor Operating at 1200 rpm

This case is similar to the previous subsection. However, the motor speed was changed from 500 rpm to 1200 rpm. Fig. 9(a) and 9(b) show only the measured CM and DM1 emissions. The DM2 and DM3 emissions were not shown here because the results were similar to those of DM1. Although, the speed of motor was changed to 1200 rpm, the compared CM and DM emissions were slightly different from the case of the induction motor operating at 500 rpm.

- Varying the 그림입니다.
원본 그림의 이름: CLP000022640015.bmp
원본 그림의 크기: 가로 68pixel, 세로 57pixel

In this subsection, R0 was changed from 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel to 1 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel. A CM attenuation of about -10 dB was gained when introducing active VSCA filters. This was especially true at a low- frequency. It should be noted that changing 그림입니다.
원본 그림의 이름: CLP000022640016.bmp
원본 그림의 크기: 가로 63pixel, 세로 71pixel did not affect the CM reduction performance of the active CSCA filters. Moreover, in terms of DM comparisons, it shows similar results in all of the cases as shown in Fig. 10 (a)-(b).


Fig. 9. Comparisons of the conducted EMI of an induction motor drive (operating at 1200 rpm): without a filter, with the conventional CM choke, with a CSCA filter (R0 = 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel), and with a VSCA filter (R0 = 10 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel). (a) CM; (b) DM1.

그림입니다.
원본 그림의 이름: image56.png
원본 그림의 크기: 가로 846pixel, 세로 403pixel

(a)

그림입니다.
원본 그림의 이름: image57.png
원본 그림의 크기: 가로 855pixel, 세로 403pixel

(b)


Fig. 10. The comparisons of conducted EMI of the induction motor drive (operating at 500 rpm) among: without filter, with conventional CM choke, with CSCA filter (R0 = 1 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel), and with VSCA filter (R0 = 1 그림입니다.
원본 그림의 이름: CLP000018a81429.bmp
원본 그림의 크기: 가로 85pixel, 세로 49pixel). (a) CM; (b) DM1.

그림입니다.
원본 그림의 이름: image58.png
원본 그림의 크기: 가로 859pixel, 세로 405pixel

(a)

그림입니다.
원본 그림의 이름: image59.png
원본 그림의 크기: 가로 855pixel, 세로 406pixel

(b)



Ⅴ. CONCLUSIONS

For three-phase induction motor drive systems, the conducted EMI reduction performance (in terms of CM, DM and total noises) of the classical passive filter (three-phase CM choke) were evaluated and compared to the cases of that with the two most popular active filters (active CSCA and VSCA filters). From the obtained experimental results, it can be concluded that the active CSCA and VSCA filters can improve the CM reduction performance of the conventional CM choke by about 5 dB. This is especially true at low-frequencies. However, for the DM comparisons, there are no significant differences between the cases with and without an inserted filter. However, the total noises can be suppressed by up to 25 dB. Improving the CM reduction performance of an active VSCA filter can be achieved by properly adjusting the value of 그림입니다.
원본 그림의 이름: CLP00001750015f.bmp
원본 그림의 크기: 가로 71pixel, 세로 75pixel. However, this cannot be done with an active CSCA filter. Moreover, from the experiments conducted in the study, it can be concluded that varying the operational speed of the motor has a slight affect on the conducted EMI level.



ACKNOWLEDGMENT

This work was supported by the research grant from Srinakharinwirot University (380/2559). Author would like to thank Miss Chompunuch Huaihongthong, Miss Ladawan Kaewaukahad, Miss Suratchada Poonsai and Mr. Sukit Ingprasert for the experimental demonstrations.



REFERENCES

[1] B. K. Bose, “Global energy scenario and impact of power electronics in 21st century,” IEEE Trans. Ind. Electron., Vol. 60, No. 7, pp. 2638-2650, Jul. 2013.

[2] R. Araneo, S. Lammens, M. Grossi, and S. Bertone,“EMC issues in high-power grid-tied photovoltaic plants,” IEEE Trans. Electromagn. Compat., Vol. 51, No. 3, pp 639-648, Aug. 2009.

[3] V. Tarateeraseth, “Systematic power line EMI filter design for SMPS, Part I: Common-mode and differential-mode conducted EMI generation mechanisms,” IEEE EMC Society Newsletters, No. 231, Fall 2011. Available: http://ewh.ieee.org/soc/emcs/newsletters.html

[4] D. Jiang, F. Wang, and J. Xue, “PWM impact on CM noise and AC CM choke for variable-speed motor drives,” IEEE Trans. Ind. Appl., Vol.49, No.2, pp. 963-972, Mar./Apr. 2013.

[5] E. Un and A. M. Hava, “A near-state PWM method with reduced switching losses and reduced common-mode voltage for three-phase voltage source inverters,” IEEE Trans. Ind. Appl., Vol. 45, No. 2, pp. 782-793, Mar./Apr. 2009.

[6] S. Payami, R. K. Behera, A. Iqbal, and R. Al-Ammari, “Common-mode voltage and vibration mitigation of a five-phase three-level npc inverter-fed induction motor drive system,” IEEE Trans. Emerg. Sel. Topics Power Electron., Vol. 3, No. 2, pp. 349-361, Jun. 2015.

[7] M. Duran, J. Prieto, F. Barrero, J. Riveros, and H. Guzman, “Space-vector PWM with reduced common-mode voltage for five-phase induction motor drives,” IEEE Trans. Ind. Electron., Vol. 60, No. 10, pp. 4159-4168, Oct. 2013.

[8] S. Karugaba, A. Muetze, and O. Ojo, “On the common- mode voltage in multilevel multiphase single- and double- ended diode-clamped voltage-source inverter systems,” IEEE Trans. Ind. Appl., Vol. 48, No. 6, pp. 2079-2091, Nov. 2012.

[9] M. C. Di Piazza, A. Ragusa, and G. Vitale, “Effects of common-mode active filtering in induction motor drives for electric vehicles,” IEEE Trans. Veh. Technol., Vol. 59, No. 6, pp. 2664-2673, Jul. 2010.

[10] S. Wang, Y. Y. Maillet, F. Wang, D. Boroyevich, and R. Burgos, “Investigation of hybrid EMI filters for common- mode EMI suppression in a motor drive system,” IEEE Trans. Power Electron., Vol. 25, No. 4, pp. 1034-1045, Apr. 2010.

[11] M. C. Di Piazza, M. Luna, and G. Vitale, “EMI reduction in DC-fed electric drives by active common-mode compensator,” IEEE Trans. Electromagn. Compat., Vol. 56, No. 5, pp. 1067-1076, Oct. 2014.

[12] A. Mallik, W. Ding, and A. Khaligh, “A comprehensive design approach to an EMI filter for a 6-kW three-phase boost power factor correction rectifier in avionics vehicular systems,” IEEE Trans. Veh. Technol., Vol. 66, No. 4, pp. 2942-2951, Apr. 2017.

[13] M. Hartmann, H. Ertl, and J. W. Kolar, “EMI filter design for a 1 MHz, 10 kW three-phase/level PWM rectifier,” IEEE Trans. Power Electron., Vol. 26, No. 4, pp. 1192-1204, Apr. 2011.

[14] P. S. Chen and Y. S. Lai, “Effective EMI filter design method for three-phase inverter based upon software noise separation,” IEEE Trans. Power Electron., Vol. 25, No. 11, pp. 2797-2806, Nov. 2010.

[15] M. L. Heldwein, H. Ertl, J. Biela, and J. W. Kolar, “Implementation of a transformerless common-mode active filter for offline converter systems,” IEEE Trans. Ind. Electron., Vol. 57, No. 5, pp. 1772-1786, May 2010.

[16] W. Chen, X. Yang, and Z. Wang, “A novel hybrid common- mode EMI filter with active impedance multiplication,” IEEE Trans. Ind. Electron., Vol. 58, No. 5, pp. 1826-1834, May 2011.

[17] D. Shin, S. Kim, G. Jeong, J. Park, J. Park, K. J. Han, and J. Kim “Analysis and design guide of active EMI filter in a compact package for reduction of common-mode conducted emissions,” IEEE Trans. Electromagn. Compat., Vol. 57, No. 4, pp. 660-671, Aug. 2015.

[18] W. Chen, W. Zhang, X. Yang, Z. Sheng, and Z. Wang, “An experimental study of common- and differential-mode active EMI filter compensation characteristics,” IEEE Trans. Electromagn. Compat., Vol. 51, No. 3, pp. 683-691, Aug. 2009.

[19] M. L. Heldwein, L. Dalessandro, and J. W. Kolar, “The three-phase common-mode inductor: Modeling and design issues,” IEEE Trans. Ind. Electron., Vol. 58, No. 8, pp. 3264-3274, Aug. 2011.

[20] K. Kostov and J. Kyyrä, “Common-mode choke coils characterization,” 13th European Conference on Power Electronics and Applications (EPE 2009), 2009.

[21] V. Tarateeraseth, “Design of three-phase line impedance stabilization networks for EMC pre-compliance testing laboratories,” the 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON 2012), 2013.

[22] V. Tarateeraseth, “A study of three-phase common-mode and differential mode conducted emission separator,” International Electrical Engineering Congress (iEECON2013), 2013.

[23] V. Tarateeraseth, K. Y. See, F. Canavero, and R.W.Y. Chang, “Systematic electromagnetic interference filter design based on information from in-circuit impedance measurement,” IEEE Trans. Electromagn. Compat., Vol. 52, No. 3, pp. 588-598, Aug. 2010.

[24] V. Tarateeraseth, “Operational amplifier gain-bandwidth product enhancement technique for common-mode active EMI filter compensation circuits,” ECTI Trans. Electr. Eng., Electron., Commun. (ECTI-EEC), Vol 11, No 2, 2013.

[25] Sergio Franco, Design with Operational Amplifiers and Analog Integrated Circuits, 3rd ed., McGraw-Hill, 2001.



그림입니다.
원본 그림의 이름: image61.jpeg
원본 그림의 크기: 가로 190pixel, 세로 236pixel

Vuttipon Tarateeraseth received his B. Eng. (with second-class honors) and M. Eng. degrees in Electrical Engineering from King’s Mongkut Institute of Technology Ladkrabang (KMITL), Bangkok, Thailand; and his Ph.D. in Electronics and Communications Engineering from Polytechnic University of Turin, Turin, Italy. From July 2008 to July 2009, he was a Visiting Researcher at the Nanyang Technological University, Singapore. He is presently working as an Associate Professor in the Department of Electrical Engineering at Srinakharinwirot University, Bangkok, Thailand. His current research interests include power electronics and electromagnetic compatibility.