The Study on the Electrical Characteristics of the Pulse Generator adopted Cascading Technique


Vol. 4, No. 2, pp. 112-116, Apr. 2004
10.6113/JPE.2004.4.2.112


PDF    

 Abstract

The pulsed power systems have been widely used many other countries and their new applications have been developed by many researchers, such as E/P(Electrostatic Precipitator) to remove the industrial dust, DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam, etc. In this paper, we studied the cascading technique as a new technology consisted of two pulse transformers and obtained their experimental data and results. To obtain the high pulsed voltage adopted cascading technique, we designed our compact pulse generator and tested by adjusting the value of the load resistors to obtain high pulsed voltage with steep rising time and duration time. We explained their experimental results that obtained by adopting cascading technique. Also, we compared theoretical value with measured value obtained by using the cascading method.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

J. Joung and M. Kim, "The Study on the Electrical Characteristics of the Pulse Generator adopted Cascading Technique," Journal of Power Electronics, vol. 4, no. 2, pp. 112-116, 2004. DOI: 10.6113/JPE.2004.4.2.112.

[ACM Style]

Jong-Han Joung and Moon-Hwan Kim. 2004. The Study on the Electrical Characteristics of the Pulse Generator adopted Cascading Technique. Journal of Power Electronics, 4, 2, (2004), 112-116. DOI: 10.6113/JPE.2004.4.2.112.