Dynamic Characteristics of DC-DC Converters Using Digital Filters


Vol. 9, No. 3, pp. 430-437, May  2009
10.6113/JPE.2009.9.3.430


PDF    

 Abstract

This paper presents the dynamic characteristics of buck and buck-boost dc-dc converters with digital filters. At first, the PID, the minimum phase FIR filter and the IIR filter controls are discussed in the buck dc-dc converter. Comparisons of the dynamic characteristics between the buck and buck-boost converters are then discussed. As a result, it is clarified that the superior dynamic characteristics are realized in the IIR filter method. In the buck converter, the undershoot is less than 2% and the transient time is less than 0.4ms. On the other hand, in the buck-boost converter, the undershoot is about 3%. However, the transient time is approximately over 4ms because the output capacitance is too large to suppress the output voltage ripple in this type of converter.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

F. Kurokawa, M. Okamatsu, T. Ishibashi, Y. Nishida, "Dynamic Characteristics of DC-DC Converters Using Digital Filters," Journal of Power Electronics, vol. 9, no. 3, pp. 430-437, 2009. DOI: 10.6113/JPE.2009.9.3.430.