Design Method for the LCL Filters of Three-phase Voltage Source PWM Rectifiers


Vol. 12, No. 4, pp. 559-566, Jul. 2012
10.6113/JPE.2012.12.4.559


PDF    

 Abstract

A new design method for the LCL filters of three-phase voltage source PWM rectifiers is presented in this paper. Based on the single-phase harmonic equivalent model, the harmonic voltage of the rectifier side is calculated to design the LCL filter parameters by an iterative algorithm, in which the resonance frequency fres and the ratio r between the grid-side inductance and the rectifier-side inductance are selected as known constants. The design criteria and process are introduced and the influence on the design result by the value of the resonance frequency fres, ratio r is analyzed. Finally an example (600V, 500kW) is tested by simulation and experiment to verify the validity of the new design method.


 Statistics
Show / Hide Statistics

Cumulative Counts from September 30th, 2019
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.



Cite this article

[IEEE Style]

X. Guo, X. You, X. Li, R. Hao, D. Wang, "Design Method for the LCL Filters of Three-phase Voltage Source PWM Rectifiers," Journal of Power Electronics, vol. 12, no. 4, pp. 559-566, 2012. DOI: 10.6113/JPE.2012.12.4.559.

[ACM Style]

Xizheng Guo, Xiaojie You, Xinran Li, Ruixiang Hao, and Dewei Wang. 2012. Design Method for the LCL Filters of Three-phase Voltage Source PWM Rectifiers. Journal of Power Electronics, 12, 4, (2012), 559-566. DOI: 10.6113/JPE.2012.12.4.559.