Phase‑shifted third harmonic modulation technique for induction heating applications to improve soft switching capability
Wonsik Jeong Kyung-Wook Heo Jun-Suk Lee Jee-Hoon Jung
Vol. 24, No. 7, pp. 1013-1023, Jul. 2024
10.1007/s43236-024-00834-0
Vol. 24, No. 7, pp. 1013-1023, Jul. 2024
10.1007/s43236-024-00834-0
Hybrid varied virtual vector modulation method of parallel three‑level inverter considering neutral point potential and phase current balance
Ying Zhong Weichao Li Liang Zhou Chen Deng Ming Yan
Vol. 24, No. 7, pp. 1024-1034, Jul. 2024
10.1007/s43236-024-00822-4
Vol. 24, No. 7, pp. 1024-1034, Jul. 2024
10.1007/s43236-024-00822-4
Optimized low switching frequency modulation with neutral point voltage control for three‐level converters
Bo Guan Chuanchuan Luo Xiaoliang Zhen
Vol. 24, No. 7, pp. 1035-1046, Jul. 2024
10.1007/s43236-024-00783-8
Vol. 24, No. 7, pp. 1035-1046, Jul. 2024
10.1007/s43236-024-00783-8
Three‑stage model predictive control for modular multilevel converters with comprehensive performance optimization
Ping Tuo Zheng Gong Xi Zheng Chun Zhao Xiaojie Wu
Vol. 24, No. 7, pp. 1047-1058, Jul. 2024
10.1007/s43236-024-00789-2
Vol. 24, No. 7, pp. 1047-1058, Jul. 2024
10.1007/s43236-024-00789-2
Backstepping control of permanent magnet synchronous motors based on load adaptive fuzzy parameter online tuning
Yufeng Zhang Qi Yan Chongchong Ai Yuecheng Wang Panpan Han
Qixun Zhou Guanghui Du
Vol. 24, No. 7, pp. 1059-1070, Jul. 2024
10.1007/s43236-024-00790-9
Qixun Zhou Guanghui Du
Vol. 24, No. 7, pp. 1059-1070, Jul. 2024
10.1007/s43236-024-00790-9
Open‑fault diagnosis and tolerant control of a dual inverter fed open‑end winding interior permanent magnet synchronous motor
Predictive field‑oriented control of three‑phase permanent magnet linear synchronous actuators
Mohammad Erfanimatin Suorena Saeedi Ali Sadighi
Vol. 24, No. 7, pp. 1081-1094, Jul. 2024
10.1007/s43236-024-00786-5
Vol. 24, No. 7, pp. 1081-1094, Jul. 2024
10.1007/s43236-024-00786-5
Analysis and design of a current suppressor to mitigate the inrush current for a low‑voltage DC distribution network
Chano Jeon Kyung-Wook Heo Jee-Hoon Jung
Vol. 24, No. 7, pp. 1095-1103, Jul. 2024
10.1007/s43236-024-00831-3
Vol. 24, No. 7, pp. 1095-1103, Jul. 2024
10.1007/s43236-024-00831-3
Distributed sliding mode consensus control of energy storage systems in wind farms for power system frequency regulation
Yinfang Zhu Linyun Xiong Changyu Ban Sunhua Huang
Vol. 24, No. 7, pp. 1104-1117, Jul. 2024
10.1007/s43236-024-00787-4
Vol. 24, No. 7, pp. 1104-1117, Jul. 2024
10.1007/s43236-024-00787-4
Physical model and long short‑term memory‑based combined prediction of photovoltaic power generation
Yaoyu Wu Jing Liu Suhuan Li Mingyue Jin
Vol. 24, No. 7, pp. 1118-1128, Jul. 2024
10.1007/s43236-024-00782-9
Vol. 24, No. 7, pp. 1118-1128, Jul. 2024
10.1007/s43236-024-00782-9
Thiran filter‐based fractional delay compensation for grid‐tied converters
Sunwoo Rhee Sungmin Lee Kwonhoon Kim Younghoon Cho
Vol. 24, No. 7, pp. 1129-1138, Jul. 2024
10.1007/s43236-024-00841-1
Vol. 24, No. 7, pp. 1129-1138, Jul. 2024
10.1007/s43236-024-00841-1
A novel power quality improved AC voltage controller for soft starting of squirrel cage induction motors
Mohamed Faizal G. Kannayeram Agnes Prema Mary
Vol. 24, No. 7, pp. 1139-1149, Jul. 2024
10.1007/s43236-024-00784-7
Vol. 24, No. 7, pp. 1139-1149, Jul. 2024
10.1007/s43236-024-00784-7
Application of a modified wavelet threshold denoising algorithm in system identification of WPTS
Qiming Huang Qijun Deng Zhifan Li Peng Luo
Vol. 24, No. 7, pp. 1150-1162, Jul. 2024
10.1007/s43236-024-00788-3
Vol. 24, No. 7, pp. 1150-1162, Jul. 2024
10.1007/s43236-024-00788-3
Integrated bus voltage control method for DC microgrids based on adaptive virtual inertia control
Liangtao Weng Ling Yang Zongyu Lei Zehang Huang Yongqiao Chen
Vol. 24, No. 7, pp. 1163-1176, Jul. 2024
10.1007/s43236-024-00785-6
Vol. 24, No. 7, pp. 1163-1176, Jul. 2024
10.1007/s43236-024-00785-6